| 1. solar charge controllers |
1. Overloading protection
2. Short circuit protection
3. Reverse current protection
4. Reverse polarity connection protection
5. Thunder protection
6. Over discharge protection
7. Overcharge protection
8. The temperature compensation
9. Analogous circuit control |
|
| Model |
Rated Voltage |
Loading current Max |
Full charge cut |
Low voltage cut |
Temperature compensation |
No load loss |
Wire area Min |
Voltage drop |
Measurement (mm) |
Gross Weight (g) |
| CMP-6A |
12V/24V auto switch |
≤6A |
13.7V |
10.5~11V |
-3mv/℃/cell |
≤20mA |
2.5m㎡ |
<120mv |
107*103*45 |
180g |
| CMP-12A |
12V/24V auto switch |
≤12A |
13.7V |
10.5~11V |
-3mv/℃/cell |
≤20mA |
2.5m㎡ |
<200mv |
107*103*45 |
180g |
| 2. solar charge controllers |
1. Overloading protection
2. Short circuit protection
3. Reverse current protection
4. Reverse polarity connecting protection
5. Thunder and lighting protection
6. Over discharge protection
Battery turns off at the voltage level, LVD sets up
7. Over charge protection
Battery stops being charged at the voltage level, HVD sets up
8. Display the capacity of the battery SOC
9. Intelligentized the temperature compensation
10. Memorize accumulated charging ampere hours on the LCD screen
11. Memorize accumulated loading ampere hours on the LCD screen
12. MCU control and LCD display |
|
| Model |
Rated Voltage |
Loading current Max |
Full charge cut |
Low voltage cut |
Temperature compensation |
No load loss |
Wire area Min |
Voltage drop |
Measurement (mm) |
Gross Weight (g) |
| CMP-20A |
12V/24V auto switch |
≤20A |
13.7V |
10.5~11V |
-3mv/℃/cell |
≤30mA |
4m㎡ |
<240mv |
150*123*55 |
420g |
| 3. Intelligent solar charge controllers |
1. Overloading protection
2. Short circuit protection
3. Reverse current protection
4. Reverse polarity connecting protection
5. Thunder and lighting protection
6. Over discharge protection
Battery turn off at the voltage level, LVD sets up
7. Over charge protection
Battery stop being charged at the voltage level, HVD sets up
8. Display the capacity of the battery SOC
9. Intelligentized the temperature compensation
10. Memorize accumulated charging ampere hours on the LCD screen
11. Memorize accumulated loading ampere hours on the LCD screen
12. MCU control and LCD display |
|
| Model |
Rated Voltage |
Loading current Max |
Full charge cut |
Low voltage cut |
Temperature compensation |
No load loss |
Wire area Min |
Voltage drop |
Measurement (mm) |
Gross Weight (g) |
| CMP-30A |
12V/24V auto switch
|
≤30A |
13.7V
Default, can be reset
|
10.5V
Default, can be reset
|
-3mv/℃/cell |
≤45mA |
6m㎡ |
<200mv |
178*162*80 |
720g |
| CMP-40A |
12V/24V auto switch
|
≤40A |
13.7V
Default, can be reset
|
10.5V
Default, can be reset
|
-3mv/℃/cell |
≤45mA |
6m㎡ |
<270mv |
178*162*80 |
720g |
| CMP-45A |
12V/24V auto switch
|
≤45A |
13.7V
Default, can be reset
|
10.5V
Default, can be reset
|
-3mv/℃/cell |
≤45mA |
6m㎡ |
<270mv |
178*162*80 |
720g |
|
|
| |
|